The U.S. Coast Guard's Engineering Analysis Board has identified factors associated with corrosion on the Coast Guard’s National Security Cutter 'Stratton'.

The Engineering Analysis Board concluded that the unusual pattern of corrosion observed on the Stratton was caused by Damage to the hull coating, caused by below-the-waterline welding, coupled with a cathodic protection system that was operating in an “underprotect” configuration contributed to the corrosion on Stratton’s hull.  Additionally, stray current corrosion from the welding was also identified as a contributing factor.

Although the corrosion issues were only limited to the Stratton the Coast Guard conducted visual inspections on both the Bertholf and Waesche. These inspections provided indication that the corrosion seen on the Stratton was an isolated incident and not a class-wide issue.

In addition to determining contributing factors, the Engineering Analysis Board provided several recommendations to prevent future occurrences of the type of corrosion experienced on Stratton, including better training on the use of cathodic protection systems and avoiding welding on wetted hull surfaces.  

The Cutter Stratton has been fully repaired and has been fully operational since March.

 

Categories: Coast Guard Coatings & Corrosion Technology

Related Stories

Adm. Kevin E. Lunday to Assume Command of the U.S. Coast Guard

Yucatán Terminal Orders Two Konecranes Mobile Harbor Cranes

Ferry Vessel Operator Upgrades Digital Experience

Current News

ONE Posts $88M Loss - Newbuild Deliveries Pressure Rates; Fleet Continues to Grow

Teamwork Required to Thwart Illegal Wildlife Trade

Longer Sailing Distances Boost Bulker Demand

Laura DiBella Designated as Chairman of FMC

Subscribe for Maritime Logistics Professional E‑News