Damaged Hull Coating Cause of Cutter Corrosion

Press Release
Monday, May 6, 2013

The U.S. Coast Guard's Engineering Analysis Board has identified factors associated with corrosion on the Coast Guard’s National Security Cutter 'Stratton'.

The Engineering Analysis Board concluded that the unusual pattern of corrosion observed on the Stratton was caused by Damage to the hull coating, caused by below-the-waterline welding, coupled with a cathodic protection system that was operating in an “underprotect” configuration contributed to the corrosion on Stratton’s hull.  Additionally, stray current corrosion from the welding was also identified as a contributing factor.

Although the corrosion issues were only limited to the Stratton the Coast Guard conducted visual inspections on both the Bertholf and Waesche. These inspections provided indication that the corrosion seen on the Stratton was an isolated incident and not a class-wide issue.

In addition to determining contributing factors, the Engineering Analysis Board provided several recommendations to prevent future occurrences of the type of corrosion experienced on Stratton, including better training on the use of cathodic protection systems and avoiding welding on wetted hull surfaces.  

The Cutter Stratton has been fully repaired and has been fully operational since March.

 

Categories: Coast Guard Coatings & Corrosion Technology

Related Stories

DP World Introduces Container Handling Technology at London Gateway

Sustainable Fuel Chicken and Egg Redux. Maybe Some Ports Can Fix It.

Liebherr Launches LiSIM ROS Simulator for Remote Operator Training

Current News

Tanco Boosts Jeffersonville Port Capacity with $750K Fertilizer Expansion

BIO-UV Completes First Containerized Ballast Water Treatment Deployment

Capesize Values Hit 17-Year High

Maritime and Coastguard Agency Advances Marine Safety with Multiverse Data Upskilling

Subscribe for Maritime Logistics Professional E‑News