Damaged Hull Coating Cause of Cutter Corrosion

Press Release
Monday, May 6, 2013

The U.S. Coast Guard's Engineering Analysis Board has identified factors associated with corrosion on the Coast Guard’s National Security Cutter 'Stratton'.

The Engineering Analysis Board concluded that the unusual pattern of corrosion observed on the Stratton was caused by Damage to the hull coating, caused by below-the-waterline welding, coupled with a cathodic protection system that was operating in an “underprotect” configuration contributed to the corrosion on Stratton’s hull.  Additionally, stray current corrosion from the welding was also identified as a contributing factor.

Although the corrosion issues were only limited to the Stratton the Coast Guard conducted visual inspections on both the Bertholf and Waesche. These inspections provided indication that the corrosion seen on the Stratton was an isolated incident and not a class-wide issue.

In addition to determining contributing factors, the Engineering Analysis Board provided several recommendations to prevent future occurrences of the type of corrosion experienced on Stratton, including better training on the use of cathodic protection systems and avoiding welding on wetted hull surfaces.  

The Cutter Stratton has been fully repaired and has been fully operational since March.

 

Categories: Technology Coatings & Corrosion Coast Guard

Related Stories

DataMondial Launches AI-Driven Service for Processing Ocean Freight Rates

Israeli Firm Gets Final Permit for US Wave Energy Demo

ABS, MPA Expand Partnership to Drive Innovation, Workforce Development

Current News

DP World, Asian Terminals Inc. Invest $100M to Boost Capacity at Manila South Harbor

PD Ports Outlines Plans to Develop UK Offshore Wind Hub

DP World Begins $165 Million Expansion of Maputo Container Terminal Capacity

Port Canaveral Invests $500 Million in Five-Year Port-Wide Improvement Plan

Subscribe for Maritime Logistics Professional E‑News