Recent port state control detentions (particularly in Australian waters) have revealed numerous cases of damaged and inoperable ballast tank air pipe heads. The air pipe heads were of the automatic float type, from different manufacturers and used by different new construction shipyards.

Investigation showed that all the air pipe heads had been damaged by being subjected to continuous overflow of the ballast tanks for ballast water exchange – a function for which they were not designed or intended to be used.

To avoid damage to automatic float-type air pipe heads, shipowners and operators should ensure that the method used for ballast water exchange is strictly in accordance with the requirements of the Ballast Water Management Convention and the guidance contained in the Lloyd’s Register approved Ballast Water Management Plan on board the vessel. This indicates which exchange method is being used. Discharging ballast water through automatic float-type closing appliances should be avoided, unless permitted within the plan.

lr.org
 

Categories: Ballast Water Treatment Classification Societies Maritime Safety Ship Repair & Conversion Government Update

Related Stories

MPA and MSC to Advance Sustainable and Digital Development

Third VLCC Exits Strait of Hormuz

US Charges Executives and Firms Over Container Cartel

Current News

New Zealand selects two LNG terminal bidders for energy security

Port Everglades Contributes $48.3b in Economic Impact, 300,000 Jobs for Florida

Report Details Four Ship Breakaways During Storm

Consortium to Advance e-Fuel Green Corridor Between Brazil and Belgium

Subscribe for Maritime Logistics Professional E‑News